Complete feature inventory

Calibration Suite Instruments & Features

Explore the instrument workflows and capabilities implemented in the current Windows build, then review additional workflows under consideration.

Current build

Implemented instrument workflows and product capabilities.

Future development

Additional workflows under review for future releases.

Expanded instrument family list

Supported Instruments

Current calibration workflows and registered instrument types are listed below. Workflow status is identified for level and flow transmitters so you can check support for your application.

PG

Current instrument family

Pressure Gauges

  • Pressure gauges / pressure indicators (PG, PI).
  • Differential-pressure gauges / indicators (DPG, PDI).
  • Five-point increasing/decreasing readings, error, tolerance, and As-Found / As-Left results.
PT

Current instrument family

Pressure Transducers

  • Electrical-output pressure devices using the pressure-transmitter calibration workflow.
  • Supported output ranges: 4–20 mA, 1–5 V, and 0–10 V.
  • Applied pressure versus expected output, As-Found / As-Left readings, tolerance, and reporting.
TI

Current instrument family

Temperature Indicators

  • Temperature indicators (TI).
  • Five-point increasing/decreasing indication checks against a temperature reference.
  • Temperature-unit or percent-span tolerance and documented results.
TX

Current instrument family

Transmitters

  • Pressure indicating transmitters (PIT).
  • Level indicating transmitters (LIT): registered instrument support; dedicated calibration workflow under review.
  • Flow indicating transmitters (FIT): registered instrument support; dedicated calibration workflow under review.
  • Temperature indicating transmitters (TIT), with RTD or thermocouple input selection.
  • 4–20 mA, 1–5 V, and 0–10 V output options; temperature indication, analog output, or both for TIT.
SW

Current instrument family

Switches

  • Pressure switches: low (PSL), high (PSH), and low-low (PSLL).
  • Differential-pressure switches: low (PDSL), high (PDSH), and high-high (PDSHH).
  • Temperature switches: low (TSL), high (TSH), low-low (TSLL), and high-high (TSHH).
  • Registered level switches: LSL, LSH, LSLL, and LSHH; dedicated calibration workflow under review.
  • Registered flow switches: FSL, FSH, FSLL, and FSHH; dedicated calibration workflow under review.
  • Set point, reset point, deadband, increasing/decreasing cycles, and pass/fail results.
RTD

Current instrument family

RTDs

  • IEC platinum types: Pt50, Pt100, Pt200, Pt500, and Pt1000.
  • Two-wire, three-wire, and four-wire connection options.
  • Resistance measurement and temperature comparison methods.
TC

Current instrument family

Thermocouples

  • Types B, E, J, K, N, R, S, and T.
  • Raw-terminal millivolt measurement with reference-junction correction.
  • Compensated millivolt measurement and temperature comparison methods.

Current build

The Complete Current Feature Set

Every confirmed capability is organized below so technicians and buyers can see exactly what the current version supports.

01

Organization

Connected Workflow & Records

  • Customer records
  • Customer site information
  • Job setup and organization
  • Technician records and reusable defaults
  • Test-equipment records and traceability
  • Reusable instrument database
  • CSV and Excel document import for instrument lists, with flexible column matching and row-by-row validation
  • Automatic workflow dates where appropriate
  • Guided Customer → Job → Instrument → Calibration → Report → History workflow
  • Save Draft, Save & Next Calibration, Save & Exit, and Finish Calibration actions
02

Current instrument support

Instrument Calibration Workflows

  • Pressure Gauges: pressure and differential-pressure gauge calibration, reference readings, error, tolerance, and final results.
  • Pressure Transducers: electrical-output pressure verification using the supported 4–20 mA, 1–5 V, or 0–10 V pressure-transmitter workflow.
  • Temperature Indicators: indication-versus-reference verification, error, tolerance, and documented results.
  • Transmitters: pressure (PIT) and temperature (TIT) calibration; registered level (LIT) and flow (FIT) instruments. Dedicated LIT/FIT calibration workflows are under review. Temperature inputs include RTD and thermocouple sensors.
  • Switches: pressure, differential-pressure, and temperature switches, with set point, reset point, deadband, and cycle results.
  • RTDs: Pt50, Pt100, Pt200, Pt500, and Pt1000 IEC sensor workflows with connection settings and resistance/temperature verification.
  • Thermocouples: types B, E, J, K, N, R, S, and T, with expected millivolts, reference-junction settings, and calibration results.
  • Engineering ranges, units, tags, service, manufacturer, model, and serial-number details carried through the record.
03

Point-by-point work

Calculations & Results

  • Pressure gauge and temperature indicator result tables
  • Five-point transmitter calibration tables
  • Five-point RTD calibration tables
  • Five-point thermocouple calibration tables
  • Switch setpoint, reset point, and deadband recording
  • Expected, As-Found, and As-Left values kept together
  • Automatic expected-output and error calculations
  • Automatic standard mA calculations
  • Free browser calculators and interactive guides for signal scaling, square-root flow, level, and sensor principles
  • Tolerance comparison and point-level pass/fail results
  • Final instrument status based on completed As-Left results
  • Set As-Left to Expected and Set As-Left to As-Found actions for RTD and thermocouple work
04

Customer deliverables

Reports & Traceability

  • Calibration reporting for Pressure Gauges, Temperature Indicators, Transmitters, Switches, RTDs, and Thermocouples
  • One instrument per one-page portrait report
  • Instrument identity, job context, range, units, tolerance, and calibration setup
  • Complete As-Found and As-Left result tables
  • Functional verification and final status
  • Comments and corrective-action documentation
  • Technician sign-off
  • Test-equipment and certificate traceability
  • Report Center / Report Manager for review and completion
  • Controlled Edit, Print Final, Close, and export actions
05

Return to the work

History & Record Retrieval

  • Calibration records retained with the related customer, job, and instrument
  • Previous jobs and reports available from history
  • Instrument activity available for later review
  • Per-instrument historical trend graphs using all retained calibration history
  • Current calibration trend compared with previous instrument performance
  • Historical data remains available for the lifetime of the instrument record
  • Customer, job, tag, and date filtering
  • Reusable records reduce repeated data entry on future work
06

Everyday operation

Settings, Equipment & Data Protection

  • Technician defaults
  • Test-equipment register
  • Test-equipment calibration due dates
  • Clear due-status indicators
  • Backup reminders
  • Backup and restore
  • Built-in glossary and help guidance
  • Local Windows-based calibration record management

Future development

Additional Instrument Workflows

Current instrument support is listed above. Future development focuses on additional and expanded level and flow workflows within these families.

Scope under reviewThese additional workflows are not confirmed as complete in the current Windows build. Scope and release timing will be confirmed after development and testing. The free browser guides demonstrate measurement principles independently of Windows calibration support.
FM

Flowmeters

Dedicated flow transmitter (FIT) and flow-switch calibration, plus magnetic, ultrasonic, and vortex flowmeter workflows, with instrument setup, test points, results, and reporting.

LV

Level Instruments

Dedicated level transmitter (LIT) and level-switch calibration workflows, including differential-pressure, radar, and ultrasonic level instruments, with documented test points and results.

See the evidence

Review the Workflow and Reports

Explore product screens and all four customer-facing report examples.